Home » Industries » Energy » Petroleum

Petroleum

Leaders in Petroleum, Upstream/Downstream, and Natural Gas Safety Solutions

Our loading platforms and access systems are built for durability and adaptability, ensuring secure and OSHA-compliant operations for LPG loading. By incorporating advanced safety features and seamless integration with existing infrastructure, SafeRack helps fuel terminals improve throughput with innovative loading racks and oil storage rack systems while maintaining worker protection and regulatory compliance.

SafeRack has been providing the oil and gas terminal industry with reliable safety solutions for years. The ever-changing footprint of oil terminals, including their extensive web of piping and equipment, creates complex access challenges. Our crossovers, work platforms, and fall protection systems provide secure and adaptable solutions to meet the industry’s evolving needs.

Designed to withstand harsh environments and frequent reconfiguration, SafeRack’s equipment is the preferred choice for fuel rack locations and petroleum terminals. Our access solutions improve worker safety, streamline maintenance, and ensure compliance with industry standards at oil loading racks and fuel terminal loading racks. By integrating robust, reconfigurable safety systems, SafeRack helps facilities enhance efficiency and protect workers in high-risk loading and storage environments.

Kenny Rogers Avatar
Petroleum
Characteristics of LPG Rail Loading
  • Product Temperature: 30°F-100°F
  • Design Temperature: -20°F-110°F
  • Normal Operating Pressure 80 – 150 psig
  • Design Pressure – 250 psig
  • Railcar Connection Size – 2” f
  • Line/Arm Size – 4”x3”x2”, 3”x2”
  • Common Hazards – Freeze burns, collapsing railcars, flammable material
Characteristics of LPG Truck Loading
  • Product Temperature: 30°F-100°F
  • Design Temperature: -20°F-110°F
  • Normal Operating Pressure: 500 PSI
  • Hydro Test Pressure: 750 PSI
  • Railcar Connection Size: 2”
  • Line/Arm Size -3”x2”
  • Common Hazards – Freeze burns, collapsing railcars, flammable material
Liquefied Petroleum Gas LPG parts

LPG Is a mixture of hydrocarbons, consisting mainly of propane, propene (propylene) and butane

  • A simplified propane supply chain would include:
    • Production and Transportation
    • Bulk Plants and Customer Delivery (cylinder filling plants, bulk storage plants, and large industrial customers)
    • End-User Customers (final consumers)
  • Propane is delivered from terminals to distributors and re-sellers via truck, railcar, ship or barge, and sometimes by pipeline, especially on the East Coast and
    Mid-West.
  • Since propane is an odorless gas, when it’s transferred from storage vessels to the loading dock an odorant is injected (Methyl Mercaptan) to detect leaks or spills.
  • LPG and anhydrous ammonia tank cars are sealed pressure containers. Several fittings are mounted on the manway cover plate to facilitate loading, unloading, gauging and testing operations.
  • Two (2) product lines
  • One (1) vapor line

Products

Crude oil sample catchers and oil thieves

We offer Tulsa Oil Thieves in three models and five sizes. All of the sample catchers feature single trip (original with the Tulsa Thief), antifouling flat-ball assembly, a full opening horizontal closure system with rotating valve, two adjustable springs (one for closing tension and one for tripping tension for more flexible adjustment) and adjustable graduated trip rods that hold the thief in an upright position as a hydrometer cylinder.

Arrow

Signs and Signals

Signs and Signals

Arrow

Drench Showers

Emergency Drench Showers and Safety Eyewash Stations

Arrow

Pipe Racks

Prefabricated Pipe Racks Constructed Faster and Easier Than Ever Before

Arrow

Tools and Loading Accessories

A comprehensive range of facility and loading terminal equipment, accessories and safety solutions.

Arrow

Grounding & Monitoring

Protect personnel, product, and terminals with static grounding (earthing) solutions

Arrow

Safety Gates

Industrial safety swing gates, facility guardrails, mezzanine gates and barriers gates.

Arrow

Spill Containment

Spill Containment

Arrow

Top Loading Arms

Top Loading Arms

Arrow

Loading Arms & Couplings

Loading Arms & Couplings

Arrow

Portable Access Platforms

SafeRack’s MAUI mobile access units provide secure, adjustable stair solutions for safely accessing elevated truck and railcar work areas, even in the most challenging environments.

Arrow

MaxRack Elevated Platforms

Powered elevating platform system for accessing railcars and trucks

Arrow

Gangways

Truck, Railcar and Marine Gangways, Safety Cages, and Inspection Services

Arrow

Stairs & Work Platforms

Fixed and Mobile Access Stairs, Work Platforms, Crossover Stairs, Rolling Stairs & Mobile Platforms, Roof Stairs and Access, Ship Ladder

Arrow

NFPA 58 – Liquefied Petroleum Gas Code

SafeRack and Fisher have collaborated to engineer a fully NFPA 58-compliant loading station, providing a safe and efficient system for LPG products (DOT 1075), NGLs, and other pressurized gases. This advanced system ensures safe access to the top of the railcar, maximizes product flow, and features remote or automatic shutdown capabilities in case of an emergency, such as fire, leaks, or railcar rollaway, eliminating the need for operator intervention.

Why NFPA 58 Compliance Matters:

  • The industry benchmark for safe LP-gas storage, handling, transportation, and usage.
  • Mitigates risks and ensures safe installations, preventing failures, leaks, and tampering that could lead to fires or explosions.
  • Many facilities lack awareness of what full compliance requires.
SafeRack’s NFPA 58-Compliant Loading Station Features:

  • Emergency Shut-off Valves (ESVs): Installed at the railcar for rapid response.
  • Snappy Joe ESVs: Positioned at the oil loading rack for enhanced safety.
  • Full System Integration: Seamless connection of loading arms, gangways, safety cages, and ESVs.
  • LPG Railcar Connections: Three connection points—two product connections and one vapor connection.
  • Step-by-Step Connection Process: Secure attachment of ESVs, vapor hoses, and system valves to create an open circuit, ensuring controlled and efficient loading.

SafeRack’s partnership with Fisher Control Valves ensures that every fuel terminal loading rack and LPG railcar loading installation meets NFPA 58 standards, providing a safer and more efficient work environment. Contact a SafeRack representative today to learn how to make your oil and gas terminal compliant and optimized for performance.

How do SafeRack’s gangways improve safety during energy product loading and unloading?

SafeRack’s self-adjusting gangways provide safe, OSHA-compliant access to tank trucks, railcars, and barges transporting crude oil, natural gas liquids, and refined fuels. Equipped with four-rail safety cages and available in powered options, our gangways minimize fall risks and ensure safe, efficient loading and unloading in high-volume energy operations.

Can SafeRack’s loading arms handle corrosive and flammable materials?

Yes. SafeRack’s carbon steel loading arms are built to safely transfer a wide range of energy products, including crude oil, LNG, and petrochemicals. With PTFE-sealed swivel joints for chemical resistance and vapor recovery systems for EPA compliance, these arms are designed to withstand harsh environments while maintaining safety and efficiency.

How does SafeRack help prevent spills and environmental hazards at energy facilities?

SafeRack provides a range of spill containment solutions, including pans, berms, and wheel chocks, to capture leaks during the transfer of oil, gas, and petrochemicals. These systems help energy facilities stay compliant with EPA regulations while protecting workers and the environment from hazardous spills.

Why is grounding important in energy loading operations, and how does SafeRack help?

Grounding is critical in energy operations to prevent static discharge, which can ignite flammable vapors during the transfer of crude oil, LNG, and refined fuels. SafeRack’s grounding and bonding systems ensure a secure ground connection before product flow begins, reducing fire and explosion risks and maintaining compliance with OSHA and NFPA standards.

Can SafeRack customize safety platforms and access systems for energy facilities?

Absolutely. SafeRack offers customizable access solutions, including gangways, platforms, stairs, and fall protection systems, specifically designed for the complex needs of energy facilities. Our modular systems are built to withstand harsh environments while improving worker safety and operational efficiency.

Projects

What Customers Are Saying

★★★★

I was most impressed by the friendliness and professionalism. The SafeRack Grounding and Monitoring Systems offered easy installation and integration with our system. I was most impressed by the friendliness and professionalism shown by Mr. McCraine in responding to all of my questions, making me feel like a priority. The speed of delivery and all other aspects of the order were satisfactory as well.

By Dan M. from JM Smucker Company

★★★★★

High quality, great design. High quality, great design, minimal amount of preventative maintenance needed.

By Jorge B. from Vale Canada Limited

★★★★★

Very Satisfied Very happy with our YellowGate. Great product!

By Carolyn K. from GK Painting

★★★★★

Great vendor, great product at a fair value. Very responsive; all who were involved were very conscientious and helpful. Solid gate and just what we were looking for to satisfy our safety audit. All staff involved were simply fantastic. Shipping was prompt and product came in in perfect condition.

By Dale C. from Pinnacle Corrugated

★★★★

Very helpful. Very helpful as I was not sure what I really was ordering but they helped me and also did not make me feel stupid that I did not know what I was doing, and I didn't have to go through a computer telephone system to talk to someone.

By Randy W. from Armstrong Machine Company, Inc

★★★★★

Cost-effective access platform to test grain in semi-trailers SafeRack's Mark Gardner was excellent to work with and he was always willing to help and change where necessary… he was very patient even throughout the 15 rounds of design changes.

By Austin H. from Gray Construction